EXguard™ Mobile Gas Detection

TN2000-5

Features

  • The standard MGD is delivered with 5 pcs IR HC gas detectors on cable drums with 40m cable, and 4 power outlets (total max. 16A) fitted on the unit
  • As an option, a separate PCU with larger power outlets (63Amps, 380-690VAC) can be provided

Marking

Ex protection control unit:
Ex II 2 G Ex dem IIC T4
Ex protection detectors:
Ex II 2 G Ex de IIC T6
Ex protection power unit:
Ex II 2 G Ex dem IIC T5

Ambient temperature

-20° C to +40 °C


Product Video


Description

The TN2000-5 is a further development of our EXguard™ System, which is designed for use on refineries and onshore plants. The TN2000-5 EXguard™ System is especially designed for use during hot work operation for onshore and offshore installations for detection, alarm and shutdown in case explosive gases are present.

The EXguard™ System consists of:

  • TN2000-5, Main Control Unit (MCU)
  • GD01 – GD05 Gas Detectors (GD)
  • TN2000-5A, Power Control Unit (PCU) (Optional)

Technical data *

Structure Lifting lugs: 2 each unit
Mobility: Wheeled, lifted
PLC: OMRON
Detector cable: Radox Tenuis-TW/S EMC
Sensor: Simrad Optronics GD10P, other sensors upon request
Dimensions Dimension Control Unit (incl. equipment):
H x W x D = 680 x 1275 x 625 mm
Dimensions Power Unit (incl. equipment):
H x W x D = 820 x 1290 x 625 mm
Material Material gas sensor and cable drum: Stainless steel 316L/CF3M
Material trolley and electrical enclosures: Stainless steel 316L/CF3M
Weight Total weight (control unit): 105 kg
Total weight (power unit): 85 kg
Voltage Rated voltage Control Unit:
220 – 240 VAC 50/60 Hz (standard)
Rated voltage Power Unit:
380 – 690 VAC 50/60 Hz (must be specified)
Current Max. current in/out Control Unit: 16A
Max. current in/out Power Unit: 63A

*Refer to the documentation for more detailed information


Documentation

Data Sheet - EXguard™ Mobile Gas Detection

Меню