Ex p control unit APEX 2003.SI (Dilution)

07-3711-4213/.001

Features

  • 4 voltage free contacts
  • 3-line LCD display
  • LED status display
  • Modular design
  • Fail-safe control
  • Integrated valve switches for purging gas input and output
  • 10 mm purging gas connection
  • Connection possibility of seperate pressure sensors

Marking

ATEX:
Ex Ex II2(1) G Ex db eb ib [ia Ga] [pxb] IIC T4 Gb
IECEx:
Ex e d ib [ia Ga px] IIC T4 Gb

Guidelines/Norms

Directive 2004/108/EC
Directive 2014/34/EU

Ambient temperature

-20 °C up to +40 °C

Certification

DMT 99 ATEX E 082
CSA 2654548
KCS KTL 13-KB4BO-0634
GOST R POCC DE.ME92.B02732

Description

The control unit APEX 2003.MV controls and monitors the purging and operating cycle of analysers with “Containment Systems“

Additional function:
Due to the internal mounting of the purging circuit, the pressurised enclosure is constantly purged with a defined quantity of purging gas.

The purging gas flow rate during purging is 4100 NI/h max. The constant purging can be set from 0 to 6.0 l/min. 4 freely programmable relay outputs are available for the separation of data lines.


Technical data *

Protection class IP 65
Structure Ex e protective enclosure with viewport lid
Material Enclosure material: glass-fiber reinforced, polyester
Purging time 0 to 99 min; 5 sec. dropout delay
Weight 11 kg
Voltage AC 230 V (AC 115 V) ±10%
Power Pv = 15 W/230 V
Connection Terminals 2.5 mm², fine stranded

*Refer to the documentation for more detailed information


Documentation

Data Sheet - Ex p control unit APEX 2003.SI (Dilution)

Declaration of Conformity 01-3711-7C0001 B

Customer requirements - Ex p equipment

Operating Instructions - Control Unit APEX 2003.SI

Меню