APEXpx control unit

Model II

07-37A2-2211/.520

Features

  • Black box system
  • Automatic calculation of the purge time
  • WEB interface
  • 3 x PT100/1000 inputs
  • Modular design
  • Safety-related control system
  • Separate purge gas input and output

Marking

ATEX:
Ex II 2(1)G Ex eb mb ib [ib pxb] [ia Ga] IIC T5, T4 Gb
Ex III 2(1)D Ex tb [ib pxb] [ia Da] IIIC T95 °C, T130 °C Db
IECEx:
Ex eb mb ib [ib pxb] [ia Ga] IIC T5, T4 Gb
Ex tb [ib pxb] [ia Da] IIIC T95 °C, T130 °C Db

Guidelines/Norms

Directive 2014/30/EU
Directive 2014/34/EU

Ambient temperature

In storage
-20 °C to +60 °C
During operation
-25 °C to +60 °C/T4
-25 °C to +50 °C/T5

Certification

BVS 19 ATEX E 015 X
IECEx BVS 19.0038x

Description

The APEXpx Ex p control unit controls and monitors the pre-purge and operating phase of pressurised enclosure equipment protected in accordance with ignition protection type px. Digital or proportional purge gas valves can be used as purge gas valves. The parameters can be set using the integrated WEB interface or the optionally available p operator panel. The APEXpx features two release relays; one which is energised and one which has floating contacts. Two signal relays with one changeover contact each are additionally available. Three PT100/1000 inputs are available to monitor the temperature of the Ex p-protected equipment. Up to three switch values can be assigned to them. Model II comes complete with integrated pressure measurement. The following components are additionally required to set up a complete control system:
– Pressure monitor
– Purge gas valve, proportional or digital
– Valve fuse
– Pressure reducer
– There is the option to connect a p operator panel


Technical data *

Protection class IP 66 according to EN/IEC 60529
IP 64 according to EN/IEC 60079-0
Material V4A stainless steel
Weight 6.8 kg

*Refer to the documentation for more detailed information


Documentation

Data Sheet - APEXpx control unit

Declaration of Conformity CE 01-37A2-7C0001

Меню