APEXmpc / SILASmpc

Zones 1 and 21

07-37A2-2211/.M5. A7-37S2-2111/.M5

Features

  • Black box system
  • Automatic calculation of the purge time
  • WEB interface
  • 3 x PT100/1000 inputs
  • Safety-related control system

Marking

ATEX:
ATEX:
Ex II 2G Ex ib IIC T4 Gb
Ex II 2(1)G Ex eb mb ib [ib pxb] [ia Ga] IIC T4 Gb
IECEx:
Ex II 2(1)D Ex tb [ib pxb] [ia Da] IIIC T130 °C Db
Ex ib IIC T4 Gb
IECEx:
Ex eb mb ib [ib pxb] [ia Ga] IIC T4 Gb
Ex tb [ib pxb] [ia Da] IIIC T130 °C Db

Guidelines/Norms

Directive 2014/30/EU
Directive 2014/34/EU

Ambient temperature

In storage
-20 °C to +60 °C
During operation
-25 °C to +50 °C
-50 °C to +50 °C (HT)

Certification

BVS 19 ATEX E 015 X
BVS 19 ATEX E 016 X (Zones 2/22)
IECEx BVS 19.0038x

Description

The APEXmpc Ex p control unit controls and monitors the pre-purge and operating phase of pressurised enclosure motors protected in accordance with ignition protection type px. The parameters can be set using the integrated WEB interface or the optionally available p operator panel. The APEXmpc features two release relays; one which is energised and one which has floating contacts. Two signal relays with one changeover contact each are additionally available.
Three PT100/1000 inputs are available to monitor the temperature of the Ex p-protected equipment. Up to three switch values can be assigned to them. All the components required to set up Ex px monitoring and purge gas valves are integrated in the APEXmpc.
The following components are additionally required
to set up a complete control system:
– “Motor purge valve MPC” outlet
– There is the option to connect a p operator panel


Technical data *

Protection class IP 66 nach EN/IEC 60529
IP 64 nach EN/IEC 60079-0
Material V4A stainless steel
Weight 40 kg

*Refer to the documentation for more detailed information


Documentation

Data Sheet - APEXmpc / SILASmpc

Declaration of Conformity 01-37A2-7C0003

Declaration of Conformity A1-37S2-7C0002

Меню