Proportional Purging Gas Valve for Ex px Operating Equipment

05-0056-00..


Marking

ATEX:
Ex II 2G Ex m II T4
IECEx:
Ex m II T4

Ambient temperature

-10 °C to +55 °C

Certification

EPS 15 ATEX 1 073 X
IECEx EPS 15.0066X

Description

The proportional purging gas valve activated by the APEX control unit conducts the supplied purging gas into the Ex px control cabinet.

During the purging phase the purging gas valve opens far enough to allow the max. purging gas pressure to be reached and accordingly ensures purging pressure in the encapsulated control cabinet.

After the purging phase the purging gas valve closes. The leakage from the Ex px control cabinet is compensated by the linear opening of the valve. Only the actual loss by leakage is compensated when the purging gas valve is used.


Technical data *

Protection class IP 65
Dimensions see data sheet
Max. Ex px control cabinet capacity: 1,000 litres
Pressure 0 to 4 bar
Weight approx. 1.2 kg
Voltage AC 230 V/15 W/50 to 60 Hz
AC 115 V/15 W/50 to 60 Hz
Voltage tolerance: ± 10%
Connection Valve connection: G 3/8″
Nominal diameter: 6.0 mm

*Refer to the documentation for more detailed information


Documentation

Data Sheet - Proportional Purging Gas Valve for Ex px Operating Equipment

Declaration of Conformity - Type 2865

Customer requirements - Ex p equipment