Local control stations for Zone 1 and Zone 21

07-3...-…./….

Features

  • The right size enclosure
  • Optimum functionality thanks to the great variety of components
  • Customised planning and implementation
  • Certified to many standards

Marking

Zone 1:
Ex II 2 G Ex db eb ma/mb op is q ia/ib [ib]
IIA, IIB, IIC, T6, T5, T4, T3 Gb
Ex II 2(1) G Ex db eb ma/mb op is q ia/ib [ia Ga]
IIA, IIB, IIC, T6, T5, T4, T3 Gb
Zone 21:
Ex II 2D Ex tb [ib] IIIA, IIIB, IIIC
T80 °C, T100 °C, T130 °C Db
Ex II 2(1) D Ex tb [ia Da] IIIA, IIIB, IIIC
T80 °C, T100 °C, T130 °C Db

Ambient temperature

(special design on request)
-20 °C to +40 °C
-55 °C max. +80 °C
(depending on fixtures)

Certification

IBExU12ATEX1099X
IECEx IBE 12.0031X
CSA 2515401
CSA 2515401 Supplement
NEPSI GYJ15.1004
TC RU C-DE.BH02.2.00177
UL-BR 11.0118
PESO P353416

Description

BARTEC produces local control stations for use in areas with flammable gases and dusts. Depending on the application area, the control stations are designed
with the type of protection “Increased safety” or “Protection by enclosure”.

The explosion-protected local control stations are available in aluminium, polyester or stainless steel. When selecting the version, you can choose between a cabinet with door and an enclosure with screw cover. Control, signalling and display devices and remote I/O systems are installed according to customer specifications. The installation of industrial standard equipment in controls for Zone 21, type of protection tb “Protection by enclosure” is possible.

The control elements can also be mounted on a mounting rail or in the front wall. Free installationa reas can be designated for the subsequent installation of BARTEC control and signalling devices, which are then sealed using blanking plugs. All explosion-protected local control stations are supplied prewired on terminals.

Fields of application

Chemical and petrochemical industry, process and plant engineering, pharmaceutical and food industry, OFF SHORE areas.


Technical data *

Protection class EN 60529/IEC 60529: IP max. IP 66
(higher degree of protection on request)
Material see data sheet
Voltage up to 1000 V
Current max. 160 A depending on devices fitted

*Refer to the documentation for more detailed information