Control Stations

TNCC


Guidelines/Norms

EN/IEC: 60079-0, 60079-1, 60079-7, 60079-18,
EN: 61241-0, 61241-1

Ambient temperature

-40 °C to +60 °C

Certification

DNV-2003-OSL-ATEX-0042
GOST PPC 00-40090
INMETRO DNV 16.0024 X

Description

The TNCC range of control stations / enclosures are manufactured in 316 stainless steel and designed to meet the requirements for use on and offshore, in petrochemical and marine applications and for any other industry where an explosive atmosphere may be present.


Technical data *

Protection class IP66 standard (67 and 68 upon request)
Material Lid/Door:
gasket Neoprene (temp. -40° C to +100° C)
Silicone (temp. -40° C to +200° C)
Surface treatment: Acidized Pickling as standard
(Electropolished as an option)
Material thickness: Min. 1.5 mm (depending on the box size)

*Refer to the documentation for more detailed information


Documentation

Data Sheet - Control Stations

Declaration of Conformity TEC-12-ATEX-TNCC-DOC-01

Customer Requirements Control Stations

Users Manual TNCC Enclosures