Relay, 1 changeover/2 changeover contacts

07-7311-937./.000


Marking

Ex II 2G Ex db e IIC Gb
Ex I M2 Ex db e I Mb
Ex db e IIC Gb
Ex db e I Mb
Class I, Zone 1, IIC
A/Ex d e IIC Gb

Guidelines/Norms

Directive 2004/108/EC
Directive 94/9/EC

Ambient temperature

-20 °C up to +40 °C

Certification

PTB 97 ATEX 1068 U
IECEx PTB 11.0083U
CSA 2484303
TC RU C-DE.BH02.B.00005
TÜV 13.1683 U

Description

The relay modules offer most up-to-date switching configurations. A suppressor diode on the coil protects the power circuit from peak voltages. The relay is used to switch power circuits up to 6 A. Thanks to its low power consumption it can be controlled by means of electronic circuits, optorelays from BARTEC or standard control circuits.


Technical data *

Protection class Module: IP 66/IEC 60529
Terminals: IP 20/IEC 60529
Material High-quality thermoplastic
Installation TH 35 x 7.5 (15) EN 60715
Mechanical life > 20 x 106 switching cycles
Storage temperature -40 °C to +70 °C
Weight 0.250 kg
Voltage see data sheet
Current see data sheet
Electrical life > 105 switching cycles for AC 230 V, 6 A ohmic load (1 changeover contact)
> 105 switching cycles for AC 230 V, 3 A ohmic load (2 changeover contact)
Connection Terminals 2.5 mm², fine stranded

*Refer to the documentation for more detailed information