Fuse max. 6.3 A

07-7311-93J2/..00


Marking

Ex II 2G Ex db e IIC Gb
Ex I M2 Ex db e I Mb
Ex d e IIC Gb
Ex d e I Mb
Class I, Zone 1, IIC
A/Ex d e IIC Gb

Guidelines/Norms

Directive 94/9/EC

Ambient temperature

-40 °C to +50 °C at T6

Certification

PTB 97 ATEX 1068 U
IECEx PTB 11.0083U
CSA 2484303
TC RU C-DE.BH02.B.00005
TÜV 13.1683 U

Description

The increasing automation of functions and processes make it necessary to install the standard protective devices on-site. Fused modules are required to protect equipment and power circuits in potentially explosive atmospheres. An advantage of control components is that they are fitted in explosion-protected enclosures with integrated double terminals.


Technical data *

Protection class Module: IP 66/IEC 60529
Terminals: IP 20/IEC 60529
Material High quality thermoplastic
Installation TH 35 x 7.5 (15) EN 60715
Storage temperature -40 °C to +70 °C
Weight 0.250 kg
Voltage 250 V
Current 3.15 A to 6.3 A (see data sheet)
Connection Terminals 2.5 mm², fine stranded
Terminal designation: written marking labels

*Refer to the documentation for more detailed information


Documentation

Data Sheet - Fuse max. 6.3 A

Declaration of Conformity 01-7311-7C0030

Brochure - MODEX